Abstract:In order to image the distribution of blood oxygen content, a blood oxygen content detection system was developed by the near infrared imaging of dual wavelengths 760 nm and 850 nm. A new simulation experiment with indocyanine green and scatterers was conducted. First, we changed the concentration of milk ΔC and detected its optical density change (ΔOD). Then indocyanine green (ICG) was dissolved in milk which was diluted 40 times. With gradient dilution of ICG, a series of curves of ΔOD-Δc were obtained. We used a linear function to fit the curves and determined the resolution of the system according to the sum of squares due to error (SSE), root mean squared error (RMSE) and coefficient of determination(R2). Third, we changed the concentration of the scattering medium to study its influence on detection. Last, 30 healthy subjects were chosen to detect the spatial distribution of blood oxygen content and its dynamic changes. The results showed the absorption coefficient ratio of milk in the dual wavelength light was closed to 1∶1 and the ratio of ICG was 2.5∶1, therefore milk could simulate water, fat and pigment, and ICG could simulate deoxygenated hemoglobin. Furthermore, the system is able to identify the minimum change of the concentration of indocyanine green of 1.6×10-5 mg/mL. With the elevation of the scatters concentration, on one hand, the scope of the system dynamic response became large; on the other hand, the sensitivity of the system became low. Finally, the blood oxygen content decreased from 1 to 0.3±0.105 during the stage of tying wrist and then recovered to 0.97±0.018 after removing the rubber band. The experiments above demonstrated the potential of application for the system in detecting tissue blood oxygen.
[1] Jobsis FF. Noninvasive, infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters [J]. Science, 1977, 198(4323):1264-1267. [2] Anderson RR, Parrish JA. The optics of human skin [J]. J Invest Dermatol, 1981, 77(1):13-19. [3] Ferrari M, Mottola L, Quaresima V. Principles, techniques, and limitations of near infrared spectroscopy [J]. Can J Appl Physiol, 2004, 29(4):463-487. [4] Hamaoka T, Chance B. The use of muscle near-infrared spectroscopy in sport, health and medical sciences: recent developments [J]. Philosophical Transactions of the Royal Society A Mathematical Physical & Engineering Sciences, 2011, 369(1955):4591-4604. [5] Nioka S, Chance B. NIR spectroscopic detection of breast cancer [J]. Technol Cancer Res Treat, 2005, 4(5):497-512. [6] 徐旭英. 糖尿病足与下肢动脉硬化闭塞症相关性研究 [D]. 北京: 北京中医药大学, 2010. [7] Bauer TA, Reusch JE, Levi M, et al. Skeletal muscle deoxygenation after the onset of moderate exercise suggests slowed microvascular blood flow kinetics in type 2 diabetes [J]. Diabetes Care, 2007, 30(11):2880-2885. [8] Carp SA, Sajjadi AY, Wanyo CM, et al. Hemodynamic signature of breast cancer under fractional mammographic compression using a dynamic diffuse optical tomography system [J]. Biomedical Optics Express, 2013, 4(12):2911-2924. [9] 丁海曙, 腾轶超, 李岳, 等. 我国首次研制出近红外组织血氧参数无损检测仪应用于临床[J]. 中国医疗器械信息, 2005, 11(3):30-30. [10] Grassi B, Pogliaghi S, Quaresima V, et al. Muscle oxygenation and pulmonary gas exchange kinetics during cycle exercise on-transitions in humans [J]. Journal of Appl Physiology, 2003, 95(1): 149-158. [11] Niyayama M. A 200-channel imaging system of muscle oxygenation using CW near-infrared spectroscopy[J].IEICE Transactions on Information & Systems, 2002, 85(1):115-123. [12] Niwayama M. Functional imaging of muscle oxygenation using a 200-channel cwNIRS system [J]. Proc SPIE, 2001, 4250:142-152. [13] 肖振. 手持式乳腺肿瘤检测仪的研制 [D]. 武汉: 华中科技大学, 2006. [14] Ferrari M, Quaresima V. A brief review on the history of human functional near-infrared spectroscopy (fNIRS) development and fields of application [J]. Neuroimage, 2012, 63(2):921-935. [15] Lee MH, Fazli S, Mehnert J, et al. Subject-dependent classification for robust idle state detection using multi-modal neuroimaging and data-fusion techniques in BCI [J]. Pattern Recognition, 2015, 48(8):2725-2737. [16] Tom L, Wright PA, Chappell PH. Optical properties of human skin [J]. J Biomed Opt, 2012, 17(9): 90901-90901. [17] Tanaka T, Benedek GB. Measurement of the velocity of blood flow (in vivo) using a fiber optic catheter and optical mixing spectroscopy [J]. Applied Optics, 1975, 14(1):189-196. [18] Li Ting, Sun Yunlong, Chen Xiao, et al. Noninvasive diagnosis and therapeutic effect evaluation of deep vein thrombosis in clinics by near-infrared spectroscopy [J]. Journal of Biomedical Optics, 2015, 20(1):010502-010502. [19] Delpy DT, Cope M, Van dZP, et al. Estimation of optical pathlength through tissue from direct time of flight measurements [J]. Physics in Medicine & Biology, 1989, 33(12):1433-1442. [20] Seiyama A, HazekiO, Tamura M. Simultaneous measurement of haemoglobin oxygenation of brain and skeletal muscle of rat in vivo by near-infrared spectrophotometry [J]. Adv Exp Med Biol, 1987, 215(215):291-295. [21] Lin Ling, Li Gang, Wang Yanqiu, et al. In vivo determination of the optical properties of human fat and muscle tissues [J]. Journal of Optoelectronics·Laser, 2001, 12(4):425-429. [22] Aernouts B, Beers RV, Watté R, et al. Effect of ultrasonic homogenization on the Vis/NIR bulk optical properties of milk [J]. Colloids & Surfaces B Biointerfaces, 2015, 126:510-519. [23] Weigand R, Rotermund F, Penzkofer A. Aggregation dependent absorption reduction of indocyanine green [J]. Journal of Physical Chemistry A, 1997, 101(42): 7729- 7734. [24] 中国科学院数学研究所数理统计组. 回归分析方法 [M]. 北京: 科学出版社, 1974: 19-36. [25] Tian Fenghua, Ding Haishu, CaiZhigang, et al. Near infrared spectroscopic assessment of oxygen delivery to free flaps on monkeys following vascular occlusions and inhalation of pure oxygen [J]. Proc SPIE, 2002, 4536:28-32.