Abstract:To improve the spatial resolution of electrical impedance tomography, a novel method based on conjugate gradient (CG) with rapid pre-reconstruction and deep stack autoencoder post-processing was proposed (Deep CG). The core idea is that the merging ofnumerical reconstruction algorithm with deeplearning-based method makes the structure and conductivity distribution of the thorax more accurate. Firstly, the mathematical reconstruction algorithm CG was adopted to pre-reconstruct the coarse image, and the mapping between boundary voltage and conductivity distribution in the chest was achieved. Next, to take full advantages of the different spatial features, the stack autoencoder was employed to connect the encoding and the decoding modules hierarchically, which realized the feature extraction (FE) and the image reconstruction (IR). Finally, to train the model, the dataset was constructed from the number of 400 clinical CT slices, a mixed supervised method was employed to adjust the model parameters, which not only avoided the dispersion of the information flow and gradient flow, but alsooptimized the parameters of Deep CG method. The relative error (RE) and correlation coefficient (CC) were adopted to evaluate the image quantitively. The images were compared to the traditionalnumerical algorithm and a full connected neural network. The results showed that the RE was decreased to 0.11 from 0.5 and 0.24, and the CC was improved to 0.96 from 0.8 and 0.9. The proposed method was able to reconstruct EIT images with higher spatial resolution and clear boundary,which is expected to put forward EIT techniques to the further applications and researches.
王子辰, 付荣, 张新宇, 王迪, 陈晓艳. 基于Deep CG的肺部电阻抗成像方法[J]. 中国生物医学工程学报, 2023, 42(2): 148-157.
Wang Zichen, Fu Rong, Zhang Xinyu, Wang Di, Chen Xiaoyan. Reconstruction of Thorax Image Based on Deep CG Method for Electrical Impedance Tomography. Chinese Journal of Biomedical Engineering, 2023, 42(2): 148-157.
[1] 王琦,陈晓静,汪剑鸣,等. 基于人体结构先验信息的胸部电阻抗成像方法[J]. 中国生物医学工程学报,2019,38(1):35-43. [2] 董秀珍. 生物电阻抗成像研究的现状与挑战[J]. 中国生物医学工程学报,2008,27(5):641-643. [3] Bayford,RH. Bioimpedance tomography (electrical impedance tomography)[J]. Annual Review of Biomedical Engineering, 2006, 8(1):63-91. [4] Brown,BH. Electrical impedance tomography (EIT):a review[J]. Journal of Medical Engineering & Technology, 2003, 27(3):97-108. [5] 任尚杰,董峰,谭超. 基于边界元与有限元耦合的ERT图像重建算法[J]. 工程热物理学报,2014(5):902-905. [6] Huang Y,Chen M,He W,et al. A parameter selecting method of newton′s one-step error reconstructor in electrical impedance tomography imaging[J]. Journal of Information & Computational Science,2013,10(3):729-741. [7] Yang Y,Wu H,Jia J. Image reconstruction for electrical impedance tomography using enhanced adaptive group sparsity with total variation[J]. IEEE Sensors Journal,2017,17(17):5589-5598. [8] Yang Y,Jia J. An image reconstruction algorithm for electrical impedance tomography using adaptive group sparsity constraint[J]. IEEE Transactions on Instrumentation & Measurement,2017,66(9):2295-2305. [9] Hinton GE,Salakhutdinov RR. Reducing the dimensionality of data with neural networks[J]. Science(New York),2006,313(5786):504-507. [10] Martin S,Choi C. On the influence of spread constant in radial basis networks for electrical impedance tomography[J]. Physiological Measurement,2016,37(6):801-819. [11] Borsoi RA,Aya JCC,Costa GH,et al. Super-resolution reconstruction of electrical impedance tomography images[J]. Computers and Electrical Engineering,2018,69:1-13. [12] Huang SW,Cheng HM and Lin SF. Improved imaging resolution of electrical impedance tomography using artificial neural networks for image reconstruction[C]//The 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC). Berlin:IEEE, 2019: 1551-1554. [13] Zheng J,Peng L. An autoencoder-based image reconstruction for electrical capacitance tomography[J]. IEEE Sensors Journal,2018,18(13):5464-5474. [14] Li X,Zhou Y,Wang J,et al. A novel deep neural network method for electrical impedance tomography[J]. Transactions of the Institute of Measurement and Control,2019,41(14):4035-4049. [15] 李峰,谭超,董峰. 全连接深度网络的电学层析成像算法[J]. 工程热物理学报,2019(7):1526-1531. [16] Tan C,Lv S,Dong F,et al. Image reconstruction based on convolutional neural network for electrical resistance tomography[J]. IEEE Sensors Journal,2018,19(1):196-204. [17] Li F,Tan C,Dong F,et al. V-Net deep imaging method for electrical resistance tomography[J]. IEEE Sensors Journal,2020,20(12):6460-6469. [18] Li F,Tan C,Dong F. Electrical resistance tomography image reconstruction with densely connected convolutional neural network[J]. IEEE Transactions on Instrumentation and Measurement,2020,70:1-11. [19] Wu Y,Chen B,Liu K,et al. Shape reconstruction with multiphase conductivity for electrical impedance tomography using improved convolutional neural network method[J]. IEEE Sensors Journal,2021,21(7):9277-9287. [20] Jin KS,Kang CK,Jargal A,et al. A learning-based method for solving ill-posed nonlinear inverse problems:a simulation study of lung EIT[J]. SIAM Journal on Imaging Sciences,2019,12(3):1275-1295. [21] Ren S,Sun K,Tan C,et al. A two-stage deep learning method for robust shape reconstruction with electrical impedance tomography[J]. IEEE Transactions on Instrumentation and Measurement,2019,69(7):4887-4897. [22] Hamilton SJ,Hauptmann A. Deep D-bar:real time electrical impedance tomography imaging with deep neural networks[J]. IEEE Transactions on Medical Imaging,2017,37(10):2367-2377. [23] Capps M and Mueller JL. Reconstruction of organ boundaries with deep learning in the D-Bar method for electrical impedance tomography[J]. IEEE Transactions on Biomedical Engineering,2021,68(3):826-833. [24] Hestenes MR,Stiefel EL. Methods of conjugate gradients for solving linear systems[J]. Journal of Research of the National Bureau of Standards (United States),1952,49(6):409-435. [25] Clark K,Vendt B,Smith K,et al. The cancer imaging archive (TCIA):maintaining and operating a public information repository[J]. Journal of Digital Imaging,2013,26(6):1045-1057. [26] Gelidi SD,Seifnaraghi N,Bardill A,et al. Towards a thoracic conductive phantom for EIT[J]. Medical Engineering & Physics,2020,77:88-94. [27] Li X,Chen X,Wang Q,et al. Electrical-impedance-tomography imaging based on a new three-dimensional thorax model for assessing the extent of lung injury[J]. AIP Advances,2019,9(12):125310. [28] Wang H,Lei T,Zhang C. An image reconstruction algorithm based on total variation with adaptive mesh refinement for ECT[J]. Flow Measurement and Instrumentation,2007,18(5-6):262-267. [29] Xu Y,Pei Y,Dong F. An adaptive Tikhonov regularization parameter choice method for electrical resistance tomography[J]. Flow Measurement and Instrumentation,2016,50:1-12. [30] Wang H,Zhu X,Zhang L. Conjugate Gradient Algorithm for Electrical Capacitance Tomography[J]. Journal of Tianjin University,2005,38(1):1-4.