Research Progress on Sensing Technology and Clinical Application of Digestive Tract PhysiologicalParameters Wireless Capsule
Hu Xiaoyu1, Feng Jie1, Zhao Xiaxia1, Huang Xiaojun1,2*
1(Department of Gastroenterology, Second Hospital of Lanzhou University, Lanzhou 730030, China) 2(Medical Engineering Research and Development Center of Gansu Province, Lanzhou 730030, China)
Abstract:The physiological mechanism of the digestive tract has been high-profile for a long time. With the rapid development of sensors and detection technologies, there has been an increasing focus on the gastrointestinal physiological parameters wireless capsules and attempts to expand their indications to solve the problem that various physiological information in the human gastrointestinal tract can be obtained difficulty. The information related to gastrointestinal motility can be acquired by micro-devices with integrated sensors, thus the dynamic curve and even peristaltic model of the digestive tract can be established to provide clinical evidence for the diagnosis and mechanism exploration of functional gastrointestinal diseases. In this review, firstly, the types, principles, and research progress of sensors applied in wireless capsules were described according to the different types of detection information. Next, a summary of the current clinical applications research status of the wireless capsules has been made, including the detection of pH, temperature, and pressure, as well as the continuous fixed-point monitoring of the physical and chemical digestive tract environment. The functional expansion research of the wireless capsules was introduced as well, such as the detection of intestinal gases, flora, digestive enzymes, etc. Finally, the R&D challenges and corresponding strategies of the wireless capsules for physiological parameters were discussed, providing useful reference information for future research in this field.
[1] Mandsberg NK, Christfort JF, Kamguyan K, et al. Orally ingestible medical devices for gut engineering[J]. Advanced Drug Delivery Reviews, 2020,165:142-154. [2] Min Jihong, Yang Yiran, Wu Zhiguang, et al. Robotics in the gut[J]. Advanced Therapeutics, 2020,3(4):1900125. [3] Miley D, Machado LB, Condo C, et al. Video capsule endoscopy and ingestible electronics: emerging trends in sensors, circuits, materials, telemetry, optics, and rapid reading software[J]. Advanced Devices & Instrumentation, 2021,11:1-30. [4] Olano C. Swallowable capsules are not only for videos[J]. Endoscopy International Open, 2019,7(6):E782-E783. [5] Beardslee LA, Banis GE, Chu S, et al. Ingestible sensors and sensing systems for minimally invasive diagnosis and monitoring: the next frontier in minimally invasive screening[J]. ACS Sensors, 2020,5(4):891-910. [6] Vonau W, Decker M, Enseleit U, et al. Is there still a need for the antimony electrode 100 years after its introduction as a pH sensor?[J]. Journal of Solid State Electrochemistry, 2020,24(11):3269-3277. [7] Rajan TS, Read TL, Abdalla A, et al. Ex vivo electrochemical pH mapping of the gastrointestinal tract in the absence and presence of pharmacological agents[J]. ACS sensors, 2020,5(9):2858-2865. [8] Avolio R, Grozdanov A, Avella M, et al. Review of pH sensing materials from macro-to nano-scale: Recent developments and examples of seawater applications[J]. Critical Reviews in Environmental Science and Technology, 2022,52(6):979-1021. [9] Tabata M, Miyahara Y. From new materials to advanced biomedical applications of solid-state biosensor: a review[J]. Sensors and Actuators B: Chemical, 2022,352:131033. [10] Cheng Chen, Wu Yue, Li Xinru, et al. A wireless, ingestible pH sensing capsule system based on iridium oxide for monitoring gastrointestinal health[J]. Sensors and Actuators B: Chemical, 2021,349:130781. [11] Sinha S, Bhardwaj R, Sahu N, et al. Temperature and temporal drift compensation for Al2O3-gate ISFET-based pH sensor using machine learning techniques[J]. Microelectronics Journal, 2020,97:104710. [12] Ghoneim MT, Nguyen A, Dereje N, et al. Recent progress in electrochemical pH-sensing materials and configurations for biomedical applications[J]]. Chem Rev, 2019,119(8):5248-5297. [13] Young SJ, Lai LT, Tang WL. Improving the performance of pH sensors with one-dimensional ZnO nanostructures[J]. IEEE Sensors Journal, 2019,19(23):10972-10976. [14] Xu Fei, Yan Guozheng, Wang Zhiwu, et al. Continuous accurate pH measurements of human GI tract using a digital pH-ISFET sensor inside a wireless capsule[J]. Measurement, 2015,64:49-56. [15] Pullano SA, Greco M, Fiorillo S, et al. Design and fabrication of an EGFET based chemical sensor using transistor association technique[C]//2020 IEEE International Symposium on Medical Measurements and Applications (MeMeA). Piscataway: IEEE, 2020:1-5. [16] Manjakkal L, Szwagierczak D, Dahiya R. Metal oxides based electrochemical pH sensors: current progress and future perspectives[J]. Progress in Materials Science, 2020,109:100635. [17] Fernandes JC, Nascimento RAS, Mulato M. Effects of measurements conditions on an extended-gate FET used as pH sensor[J]. Materials Research, 2016,19:267-272. [18] Ali AMA, Ahmed NM, Mohammad SM, et al. Effect of gamma irradiation dose on the structure and pH sensitivity of ITO thin films in extended gate field effect transistor[J]. Results in Physics, 2019,12:615-622. [19] Sharma P, Gupta S, Singh R, et al. Hydrogen ion sensing characteristics of Na3BiO4-Bi2O3 mixed oxide nanostructures based EGFET pH sensor[J]. International Journal of Hydrogen Energy, 2020,45(37):18743-18751. [20] Mishra RB, El-Atab N, Hussain AM, et al. Recent progress on flexible capacitive pressure sensors: from design and materials to applications[J]. Advanced Materials Technologies, 2021,6(4):2001023. [21] Yang Xiaofeng, Chen Si, Shi Yijun, et al. A flexible highly sensitive capacitive pressure sensor[J]. Sensors and Actuators A: Physical, 2021,324:112629. [22] Benken A, Gianchandani Y. Passive wireless pressure sensing for gastric manometry[J]. Micromachines (Basel), 2019,10(12):868. [23] Alsunaydih FN, Arefin MS, Redoute J-M, et al. A navigation and pressure monitoring system toward autonomous wireless capsule endoscopy[J]. IEEE Sensors Journal, 2020,20(14):8098-8107. [24] Arefin MS, Redouté JM, Yuce MR. Integration of low-power ASIC and MEMS sensors for monitoring gastrointestinal tract using a wireless capsule system[J]. IEEE Journal of Biomedical and Health Informatics, 2017,22(1):87-97. [25] Faudzi AAM, Sabzehmeidani Y, Suzumori K. Application of micro-electro-mechanical systems (MEMS) as sensors: a review[J]. Journal of Robotics and Mechatronics, 2020,32(2):281-288. [26] Sharova AS, Melloni F, Lanzani G, et al. Edible electronics: The vision and the challenge[J]. Advanced Materials Technologies, 2021,6(2):2000757. [27] Liao CH, Cheng CT, Chen CC, et al. An ingestible electronics for continuous and real-time intraabdominal pressure monitoring[J]. J Pers Med, 2020,11(1):12. [28] Curry EJ, Ke K, Chorsi MT, et al. Biodegradable piezoelectric force sensor[J]. Proceedings of the National Academy of Sciences, 2018,115(5):909-914. [29] Xu Wenwen, Yang Haikai, Zeng Wei, et al. Food-based edible and nutritive electronics[J]. Advanced Materials Technologies, 2017,2(11):1700181. [30] Dobashi Y, Yao D, Petel Y, et al. Piezoionic mechanoreceptors: force-induced current generation in hydrogels[J]. Science, 2022,376(6592):502-507. [31] 路喜月, 李政, 于秋灵, 等. 水凝胶pH传感器新技术的研究进展[J]. 分析化学,2022,50(2):163-172. [32] Scarpa E, Mastronardi V, Guido F, et al. Wearable piezoelectric mass sensor based on pH sensitive hydrogels for sweat pH monitoring[J]. Scientific Reports, 2020,10(1):1-10. [33] Liu Xinyue, Steiger C, Lin Shaoting, et al. Ingestible hydrogel device[J]. Nature Communications, 2019,10(1):1-10. [34] Xu Fei, Yan Guozheng. Toward a wireless electronic capsule with microsensors for detecting dysfunction of human gastric motility[J]. IEEE Sensors Journal, 2014,15(4):2194-2202. [35] Kim A, Powell C, Ziaie B. A Universal packaging technique for low-drift implantable pressure sensors[J]. Biomedical Microdevices, 2016,18(2):1-8. [36] Zhao Kai, Zhuang Haoyu, Cui Liu, et al. A packaging technique of pressure sensor for in vivo measurement system[J]. Sensors and Actuators A: Physica, 2022,340:113514. [37] Bongers CC, Hopman MT, Eijsvogels TM. Validity and reliability of the myTemp ingestible temperature capsule[J]. Journal of Science and Medicine in Sport, 2018,21(3):322-326. [38] Xu Fei, Yan Guozheng, Zhao Kai, et al. A wireless capsule system with ASIC for monitoring the physiological signals of the human gastrointestinal tract[J]. IEEE Transactions on Biomedical Circuits and Systems, 2014,8(6):871-880. [39] Bogerd CP, Velt K, Annaheim S, et al. Comparison of two telemetric intestinal temperature devices with rectal temperature during exercise[J]. Physiological Measurement, 2018,39(3):03NT01. [40] Rajbhandary P, Nallathambi G. Validity and reliability of oral temperature compared to ingestible core temperature pill in free-living conditions[EB/OL]. https://arxiv.org/abs/2108.00537v1,2021-08-01/2022-01-20. [41] Barrie S, Murray MT. Heidelberg pH capsule gastric analysis[M]//Churchill Livingstone. Textbook of Natural Medicine. Amsterdam: Elsevier, 2020:154-156. [42] Deraman MA, Abdul Hafidz MI, Lawenko RM, et al. Randomised clinical trial: the effectiveness of Gaviscon Advance vs non-alginate antacid in suppression of acid pocket and post-prandial reflux in obese individuals after late-night supper[J]. Alimentary Pharmacology & Therapeutics, 2020,51(11):1014-1021. [43] Johannessen EA, Wang Lei, Wyse C, et al. Biocompatibility of a lab-on-a-pill sensor in artificial gastrointestinal environments[J]. IEEE Transactions on Biomedical Engineering, 2006,53(11):2333-2340. [44] Steenackers N, Wauters L, Van der Schueren B, et al. Effect of obesity on gastrointestinal transit, pressure and pH using a wireless motility capsule[J]. Eur J Pharm Biopharm, 2021,167:1-8. [45] Okamoto LE, Celedonio JE, Smith EC, et al. Local passive heat for the treatment of hypertension in autonomic failure[J]. Journal of the American Heart Association, 2021,10(7):e018979. [46] Wu Jiansong, Hu Zhuqiang, Han Zhaoxin, et al. Human physiological responses of exposure to extremely cold environments[J]. Journal of Thermal Biology, 2021,98:102933. [47] Kyriacou P. Biomedical Sensors:Temperature sensor technology[M]//Sensors Technology Series: Biomedical Sensors. NewYork: Momentum Press, 2010:1-38. [48] Chapon P, Gauthier A, Bulla J, et al. Innovative gastrointestinal telemetric temperature sensor[C]//European Medical Physics and Engineering Conference. Sofia: ResearchGate, 2012: 172-179. [49] Kalantar-Zadeh K, Berean KJ, Burgell RE, et al. Intestinal gases: influence on gut disorders and the role of dietary manipulations[J]. Nature Reviews Gastroenterology & Hepatology, 2019,16(12):733-747. [50] 2020年中国胃食管反流病内镜治疗专家共识[J].中华消化内镜杂志, 2021,38(1):1-12. [51] Cummins G. Smart pills for gastrointestinal diagnostics and therapy[J]. Advanced Drug Delivery Reviews, 2021,177:113931. [52] Ang D, Teo EK, Ang TL, et al. To Bravo or not? A comparison of wireless esophageal pH monitoring and conventional pH catheter to evaluate non-erosive gastroesophageal reflux disease in a multiracial Asian cohort[J]. Journal of Digestive Diseases, 2010,11(1):19-27. [53] Elias K, Hellström PM, Webb DL, et al. Gastrointestinal physiology before and after duodenal switch with comparisons to unoperated lean controls: novel use of the smartpill wireless motility capsule[J]. Obesity Surgery, 2021,31(8):3483-3489. [54] Farmer AD, Scott SM, Hobson AR. Gastrointestinal motility revisited: the wireless motility capsule[J]. United European Gastroenterology Journal, 2013,1(6):413-421. [55] Broesder A, Woerdenbag HJ, Prins GH, et al. pH-dependent ileocolonic drug delivery, part I: In vitro and clinical evaluation of novel systems[J]. Drug Discov. Today, 2020,25:1362-1373. [56] Kessels SJ, Newton SS, Morona JK, et al. Safety and efficacy of wireless pH monitoring in patients suspected of gastroesophageal reflux disease[J]. Journal of Clinical Gastroenterology, 2017,51(9):777-788. [57] Rehan M, Al-Bahadly I, Thomas DG, et al. Measurement of peristaltic forces exerted by living intestine on robotic capsule[J]. IEEE/ASME Transactions on Mechatronics, 2021,26(4):1803-1811. [58] Huang Fanyu, Magnin C, Brouqui P. Ingestible sensors correlate closely with peripheral temperature measurements in febrile patients[J]. Journal of Infection, 2020,80(2):161-166. [59] Lazaro P, Momayez M. Development of a modified predicted heat strain model for hot work environments[J]. International Journal of Mining Science and Technology, 202030(4):477-481. [60] Stevens CJ, Ross ML, Périard JD, et al. Core temperature responses to elite Racewalking competition[J]. International Journal of Sports Physiology and Performance, 2020,15(6):892-895. [61] Azzam RS, Azzam GB, Nasi A. Wireless ph monitoring and conventional esophageal ph monitoring: comparative study of discomfort, limitations in daily activities and complications[J]. Arquivos Brasileiros de Cirurgia Digestiva (São Paulo), 2021,34(1):e1566. [62] Travers GJ, Nichols DS, Farooq A, et al. Validation of an ingestible temperature data logging and telemetry system during exercise in the heat[J]. Temperature, 2016,3(2):208-219. [63] de Korte JQ, Bongers CC, Hopman MT, et al. Performance and thermoregulation of dutch olympic and paralympic athletes exercising in the heat: rationale and design of the Thermo Tokyo study: The journal Temperature toolbox[J]. Temperature, 2021,8(3):209-222. [64] Bongers CC, Daanen HA, Bogerd CP, et al. Validity, reliability, and inertia of four different temperature capsule systems[J]. Medicine & Science in Sports & Exercise, 2018,50(1):169-175. [65] Ding Zhen, Wang Weijun, Zhang Kun, et al. Novel scheme for non-invasive gut bioinformation acquisition with a magnetically controlled sampling capsule endoscope[J]. Gut, 2021,70(12):2297-2306. [66] 严晓南. 新型压力胶囊内窥镜系统的动物实验研究与初步临床应用[D]. 上海:中国人民解放军海军军医大学, 2018. [67] Kalantar-Zadeh K, Berean KJ, Ha N, et al. A human pilot trial of ingestible electronic capsules capable of sensing different gases in the gut[J]. Nature Electronics, 2018,1(1):79-87. [68] Daeffler KNM, Galley JD, Sheth RU, et al. Engineering bacterial thiosulfate and tetrathionate sensors for detecting gut inflammation[J]. Molecular Systems Biology, 2017,13(4):923. [69] Zhu Chengjie, Wen Yuhan, Liu Tao, et al. A packaged ingestible bio-pill with 15-pixel multiplexed fluorescence nucleic-acid sensor and bi-directional wireless interface for in-vivo bio-molecular sensing[C]//2020 IEEE Symposium on VLSI Circuits. Piscataway: IEEE, 2020:1-2. [70] Singh S, Allan N, Wahl C, et al. Development of a swallowable diagnostic capsule to monitor gastrointestinal health[J]. Gastroenterology, 2019,156(Suppl 1):S376. [71] Jeffery IB, Das A, O’Herlihy E, et al. Differences in fecal microbiomes and metabolomes of people with vs without irritable bowel syndrome and bile acid malabsorption[J]. Gastroenterology, 2020,158(4):1016-1028. [72] Kühn T, Stepien M, López-Nogueroles M, et al. Prediagnostic plasma bile acid levels and colon cancer risk: a prospective study[J]. JNCI: Journal of the National Cancer Institute, 2020,112(5):516-524. [73] Humbert L, Rainteau D, Tuvignon N, et al. Postprandial bile acid levels in intestine and plasma reveal altered biliary circulation in chronic pancreatitis patients[J]. Journal of Lipid Research, 2018,59(11):2202-2213. [74] Banis GE, Beardslee LA, Stine JM, et al. Capacitive sensing of triglyceride film reactions: a proof-of-concept demonstration for sensing in simulated duodenal contents with gastrointestinal targeting capsule system[J]. Lab on a Chip, 2020,20(11):2020-2032. [75] 贺术, 张震, 颜国正. 扩张-伸缩式机器人在肠道中的力学特性研究[J]. 北京生物医学工程, 2019,38(1):59-66. [76] 孟一村, 颜国正, 汪炜, 等. 用于微型胃肠道胶囊机器人供能的U型发射线圈无线能量传输系统设计与实验[J]. 光学精密工程, 2021,29(8):1881-1890. [77] Chen Fanji, Jiang Pingping, Yan Guozheng, et al. Design of multi-coil wireless power transfer system for gastrointestinal capsule robot[J]. Journal of Shanghai Jiaotong University (Science), 2021,26(1):76-83. [78] Hosoe N, Takabayashi K, Ogata H, et al. Capsule endoscopy for small-intestinal disorders: current status[J]. Digestive Endoscopy, 2019,31(5):498-507. [79] Dimoulas C, Kalliris G, Papanikolaou G, et al. Bowel-sound pattern analysis using wavelets and neural networks with application to long-term, unsupervised, gastrointestinal motility monitoring[J]. Expert Systems with Applications 2008,34(1):26-41. [80] Zan Peng, Zhao Yutong, Sui Jinke, et al. Research of LMD-STFT algorithm based on wavelet packet in rectal dynamic function diagnosis[C]//The 40th Chinese Control Conference (CCC), Piscataway: IEEE, 2021:6356-6361. [81] 任小梅, 杨刚. 基于模糊聚类技术的肌电信号完全分解算法[J]. 计算机应用, 2016,36(3):878-882. [82] Khan MU, Aziz S, Sohail M, et al. Automated detection and classification of gastrointestinal diseases using surface-EMG signals[C]//The 22nd International Multitopic Conference (INMIC), Piscataway: IEEE, 2019:1-8. [83] Mazloom R. A new approach for digestive disease diag Dr. Zohaib Iqbanosis: dynamics of gastrointestinal electrical activity[J]. Medical Hypotheses, 2019,128:64-68. [84] Alagumariappan P, Krishnamurthy K. An approach based on information theory for selection of systems for efficient recording of electrogastrograms[C]//Proceedings of the International Conference on Computing and Communication Systems. Berlin: Springer-Verlag, 2018:463-471. [85] Valdastri P, Quaglia C, Susilo E, et al. Wireless therapeutic endoscopic capsule: in vivo experiment[J]. Endoscopy, 2008,40(12):979-982. [86] Yu Jin, Qian Yangyang, He Chaohui, et al. Safety and efficacy of a new smartphone-controlled vibrating capsule on defecation in beagles[J]. Scientific Reports, 2017,7(1):1-7.