|
|
Study on the Primary Stability of Implants post Immediate Implantation |
You Jia, Zhou Lefeng, Peng Wei*, Gao Yilin, Yao Chunyan |
(Key Laboratory of E&M (Zhejiang University of Technology), Ministry of Education & Zhejiang Province,Hangzhou 310014,China) |
|
|
Abstract A good primary stability post immediate implantation was the key factor to achieve success of implantation. The bone defect due to periodontitis, trauma or tooth extraction, the magnitude of interference between the implant and tooth socket could affect the primary stability of implants. This article established a new classification model for the degree of bone wall defect, and with the help of finite element software ABAQUS. The classification could acquire the root-analogue implant’s primary stability with different interference and defective degree of bone wall. Next, inserting implant in analog bone to comparative analysis. Results showed that primary stability became higher with the increase of magnitude of interference, and with the increase of bone defect degree, primary stability declined. In the three walls of bone defect, when there was no interference between the implant and tooth socket, the implant stability quotient(ISQ) was less than 40; and when the magnitude of interference was 0.2mm, the ISQ values were all over 50. It was shown that the interference made a great effect on the primary stability. The ISQ values were almost below 40 when the bone around implant was one wall of bone defect, and we should increase the magnitude of interference to increase primary stability. According to the different degree of bone defect, the required magnitude of interference was different. The established classification could provide theoretical basis for custom-made root-analogue implant in the future.
|
Received: 17 September 2015
|
|
|
|
|
[1] Adell R, Lekholm U, Rockler B, et al. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw[J]. Int J Oral Surg, 1981, 10(6): 387-416. [2] Adell R, Eriksson B, Lekholm U, et al. Long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws[J]. The International Journal of Oral & Maxillofacial Implants, 1990, 5(4): 347-359. [3] Koh RU, Rudek I, Wang HL. Immediate implant placement: positives and negatives[J]. Implant Dentistry, 2010, 19(2): 98-108. [4] 伍颖颖,宫苹.种植体初期稳定性的研究现状与进展[J]. 国际口腔医学杂志, 2009, 36(6):726-728. [5] Figliuzzi M, Mangano F, Mangano C. A novel root analogue dental implant using CT scan and CAD/CAM: selective laser melting technology[J]. International Association of Oral and Maxillofacial Surgeons, 2012, 41: 858-862. [6] 游嘉,方利华,张青,等. 基于SLM技术的表面多孔钛金属多根牙种植体的骨结合研究[J]. 中国生物医学工程学报,2015,34(3):315-322. [7] Elias CN, Rocha FA, Nascimento AL, et al. Influence of implant shape, surface morphology, surgical technique and bone quality on the primary stability of dental implants[J]. Journal of the Mechanical Behavior of Biomedical Materials, 2012, 16: 169-180. [8] Shirazi-Adl A, Dammak M, Zukor DJ. Fixation pull-out response measurement of bone screws and porous-surfaced posts[J]. Journal of Biomechanics, 1994, 27(10): 1249-1257. [9] Hsu JT, Huang HL, Chang CH, et al. Relationship of three-dimensional bone-to-implant contact to primary implant stability and peri-implant bone strain in immediate loading: microcomputed tomographic and in vitro analyses[J]. The International Journal of Oral & Maxillofacial Implants, 2013, 28(2): 367-374. [10] 孟焕新. 牙周病学[M]. 北京:人民卫生出版社,2008:105-113. [11] Cawley P, Pettersson A. Method and arrangement relating to testing objects. US8391958B2[P]. 2013-05. [12] Huang HM, Lee SY, Yeh CY,et al. Resonance frequency assessment of dental implant stability with various bone qualities: a numerical approach[J]. Clinical Oral Implants Research, 2002, 13(1): 65-74. [13] 董星涛,王长志,李文俊. SLS激光功率与烧结件弹性模量关系研究[J]. 中国制造业信息化, 2012, 41(19): 51-54. [14] Jee WS. Principles in bone physiology[J]. J Musculoskelet Neuronal Interact, 2000, 1(1): 11-13. [15] 高亦林,游嘉,彭伟,等. 个性化拟自然牙种植体的设计及有限元分析[J]. 中国口腔种植学杂志,2015,20(2):62-65. |
|
|
|