|
|
Single-Lead ECG Chest Band Based on Multi-Layer Screen Printing Flexible Dry Electrode |
Jiang Yuchen1, Zhang Yue1, Cha Xingzeng1, Su Ye2, Lai Dakun1* |
1(School of Electronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu 610054, China) 2(Department of Cardiovascular Ultrasound and Cardiac Function, Sichuan Provincial People′sHospital, Chengdu 610072, China) |
|
|
|
Received: 08 October 2022
|
|
Corresponding Authors:
*E-mail: dklai@uestc.edu.cn
|
|
|
|
[1] Myers A C, Huang H, Zhu Y. Wearable silver nanowire dry electrodes for electrophysiological sensing[J]. Rsc Advances, 2015, 5(15): 11627-11632. [2] Choi S B, Oh MS, Han CJ, et al. Conformable, thin, and dry electrode for electrocardiography using composite of silver nanowires and polyvinyl butyral[J]. Electronic Materials Letters, 2019, 15: 267-277. [3] Yun I, Jeung J, Lim H, et al. Stable bioelectric signal acquisition using an enlarged surface-area flexible skin electrode[J]. ACS Applied Electronic Materials, 2021, 3(4): 1842-1851. [4] Sun B, McCay RN, Goswami S, et al. Gas‐permeable, multifunctional on‐skin electronics based on laser‐induced porous graphene and sugar‐templated elastomer sponges[J]. Advanced Materials, 2018, 30(50): 1804327. [5] Xu X, Liu Z, He P, et al. Screen printed silver nanowire and graphene oxide hybrid transparent electrodes for long-term electrocardiography monitoring[J]. Journal of Physics D: Applied Physics, 2019, 52(45): 455401. [6] Ying B, Wu Q, Li J, et al. An ambient-stable and stretchable ionic skin with multimodal sensation[J]. Materials Horizons, 2020, 7(2): 477-488. [7] Webster JG. Medical Instrumentation: Application and Design [M]. New York: John Wiley & Sons, 2009. [8] Chi YM, Jung TP, Cauwenberghs G. Dry-contact and noncontact biopotential electrodes: Methodological review[J]. IEEE Reviews in Biomedical Engineering, 2010, 3: 106-119. [9] Lai D, Bu Y, Su Y, et al. A flexible multilayered dry electrode and assembly to single-lead ECG patch to monitor atrial fibrillation in a real-life scenario [J]. IEEE Sensors Journal, 2020, 22: 12295-12306. [10] Di Rienzo M, Vaini E, Lombardi P. Development of a smart garment for the assessment of cardiac mechanical performance and other vital signs during sleep in microgravity[J]. Sensors and Actuators A: Physical, 2018, 274: 19-27. [11] Cho H, Lee JH. A study on the optimal positions of ECG electrodes in a garment for the design of ECG-monitoring clothing for male[J]. Journal of Medical Systems, 2015, 39: 1-14. [12] Winter BB, Webster JG. Driven-right-leg circuit design[J]. IEEE Transactions on Biomedical Engineering, 1983,30: 62-66. [13] Bu Y, Hassan MFU, Lai D. The embedding of flexible conductive silver-coated electrodes into ECG monitoring garment for minimizing motion artefacts[J]. IEEE Sensors Journal, 2020, 21: 14454-14465. [14] Weder M, Hegemann D, Amberg M, et al. Embroidered electrode with silver/titanium coating for long-term ECG monitoring[J]. Sensors, 2015, 15(1): 1750-1759. [15] Lee JW, Yun KS. ECG monitoring garment using conductive carbon paste for reduced motion artifacts[J]. Polymers, 2017, 9(9): 439. [16] Jung HC, Moon JH, Baek DH, et al. CNT/PDMS composite flexible dry electrodes for long-term ECG monitoring[J]. IEEE Transactions on Biomedical Engineering, 2012, 59(5): 1472-1479. |
|
|
|