前列腺癌磁共振电阻抗成像新方法 |
1 厦门理工学院电气工程与自动化学院, 福建 厦门 361024
2 厦门理工学院光电与通信工程学院, 福建 厦门 361024 |
|
A Novel Method of Magnetic Resonance Electrical Impedance Tomography for Prostate Cancer Detection |
1 School of Electrical Engineering and Automation, Xiamen University of Technology, Xiamen 361024, Fujian, China
2 School of OptoElectronic and communication Engineering, Xiamen University of Technology, Xiamen 361024, Fujian, China |
[1]Siegel R, Ward E, Brawey O, et al. Cancer statistics,2011: the impact of eliminating socioeconomic and racial disparities on premature cancer deaths [J]. Cancer J Clin, 2011, 61(4):212-236.
[2]Borsic A, Halter R, Wan Y, et al. Sensitivity study and optimization of a 3D electric impedance tomography prostate probe [J]. Physiol Meas,2009, 30(6): 1-22.
[3]Borsic A, Halter R, Wan Y, et al.Electrical impedance tomography reconstruction for threedimensional imaging of the prostate [J]. Physiol Meas,2010,31(8): 1-18.
[4]Halter R J, Schned A, Heaney J, et al. Electrical impedance spectroscopy of benign and malignant prostatic tissues [J]. J Urol, 2008,179(4): 1580-1586.
[5]Halter R J, Schned A, Heaney J, et al. Electrical properties of prostatic tissues: I single frequency admittivity properties [J]. J Urol,2009,182(4): 1600-1607.
[6]Borsic A, Halter R, Wan Y, et al. Sensitivity study of a 3D electrical impedance tomography prostate probe [C]// Proceedings of World Congress on Medical Physics and Biomedical Engineering. Munich: Springer, 2009,25: 673-676.
[7]Wan Y, Halter R, Borsic A, et al. Sensitivity study of an ultrasound coupled transrectal electrical impedance tomography system for prostate imaging [J]. Physiol Meas,2010,31(8): 17-29.
[8]Jossinet J, Marry E, Montalibet A. Electrical impedance endotomography: imaging tissue from inside [J]. IEEE Trans Biomed Eng, 2002,21(6): 560-565.[9]Jossinet J, Desseux A. Electrical impedance endotomography: sensitivity distribution against bipolar current patterns [J]. Physiol Meas,2004,25(1): 355-364.
[10]Jossinet J, Desseux A, Matias A. Assessment of electrical impedance endotomography for hardware specification [J]. Biomed Imaging Interv J, 2006,2(2): e24.
[11]Kim H J, Jeong W C, Kim YT, et al. In Vivo conductivity imaging of canine male pelvis using a 3T MREIT system [C]// J Phys Conf Ser, 2010,224:012020.
[12]Liu Yang, Zhu Sanan, He Bin. Induced current magnetic resonance electrical impedance tomography of brain tissues based on Jsubstitution algorithm: a simulation study [J]. Phys Med Biol,2009,54(14): 4561-4573.
[13]Rush S, Abildskov JA, Mcfee R. Resistivity of body tissues at low frequencies [J]. Circ Res, 1963,12(8): 40-50.
[14]Arpinar V E, Hamamura M J, Degirmenci E, et al. MREIT experiments with 200 μA injected currents: a feasibility study using two reconstruction algorithms, SMM and harmonic Bz [J]. Phys Med Biol, 2012, 57(13): 4245-4261.
[15]Giland O, Horesh L and Holder D S. Design of electrodes and current limits for low frequency electrical impedance tomography of the brain [ J]. Med Bio Eng Comput, 2007,45(7): 621-633.
[16]Lee BI, Oh SH, Kim T, et al. Basic setup for breast conductivity imaging using magnetic resonance electrical impedance tomography [J]. Phys Med Biol, 2006, 51(2): 443-455.
|
[1] |
林晓红1 闫铮1* 程继伟2 朱新建3. 基于Gabor特征的MRI椎间盘定位与退行性变分级算法研究[J]. 中国生物医学工程学报, 2015, 34(6): 736-742. |
[2] |
支联合1* 周文刚2 谭素敏3. 基于多尺度特征提取的t检验方法分析fMRI数据[J]. 中国生物医学工程学报, 2015, 34(4): 492-495. |
[3] |
张孝琴1 李建策1 王娜娜1 杨运俊1 吴立军2*注射流率对脑磁共振灌注成像血流动力学的影响[J]. 中国生物医学工程学报, 2015, 34(2): 253-256. |
[4] |
辛学刚1,2*. 人体组织电特性磁共振断层成像(MR EPT)技术进展[J]. 中国生物医学工程学报, 2015, 34(1): 83-90. |
[5] |
尧德中#* 吴丹 赖永秀 龚殿坤 罗程 卢竟 马维毅 杨华 徐鹏. 基于脑电和磁共振的音乐脑机制研究[J]. 中国生物医学工程学报, 2014, 33(6): 673-676. |
[6] |
程思佳 景斌 李海云#*. 人脑对握力刺激响应特征的数值计算分析方法[J]. 中国生物医学工程学报, 2014, 33(3): 266-273. |
[7] |
吴双1 邱天爽1*. 基于稀疏表示和脉冲耦合神经网络的医学影像融合算法[J]. 中国生物医学工程学报, 2013, 32(4): 448-453. |
[8] |
吴锡1,2 * 何晋1 王玉1 谢明元1 周激流2. 改进Wiener 滤波弥散加权磁共振图像Rician 噪声复原[J]. 中国生物医学工程学报, 2013, 32(2): 135-140. |
[9] |
范文茹1*王化祥2 郝魁红1 马敏1基于TwIST-TV正则化算法的肺萎陷电阻抗成像仿真研究[J]. 中国生物医学工程学报, 2013, 32(1): 1-6. |
[10] |
王迪 黄绮华 辛学刚*. 混合MOM/FDTD电磁分析方法及其在MR射频线圈设计中的应用[J]. 中国生物医学工程学报, 2012, 31(2): 262-267. |
[11] |
冀倩倩包家立1*李宇波2 朱朝阳1. 磁共振成像的电磁安全与限值标准[J]. 中国生物医学工程学报, 2012, 31(1): 141-146. |
|
|
|
|