Abstract:Due to high accuracy and minimal invasive, robotic surgery has been widely accepted by surgeons. However, the lack of intraoperative sense of touch (haptic feedback) can increase uncertainty and bring risks in the surgery, which is regarded as the biggest limitation of the robot surgery and require further development. In this article, haptic feedback system was reviewed from the system composition, key techniques and current research status. Haptic feedback includes force feedback and tactile feedback. The implementation of the system relies on the haptic sense and display.Commonly used haptic sensor, display device, sensory substitution techniques and the analysis on the corresponding advantages and disadvantages were introduced in the review. Research progress of the haptic feedback system in surgical robot was outlined as well. At last, the future research direction was suggested on the basis of the previous studies.
郭松 杨明杰 谭军*. 手术机器人面临的一大挑战———力触觉反馈[J]. 中国生物医学工程学报, 2013, 32(4): 499-503.
GUO Song YANG MingJie TAN Jun*. A Big Challenge of Surgical Robot—Haptic Feedback. journal1, 2013, 32(4): 499-503.
[1]Kenoki O,Makoto H. Robotic surgery for cancer[J]. The Cancer Journal, 2013,19(2) :130-132.
[2]Marescaux J, Smith MK, Folscher D, et al. Telerobotic laparoscopic cholecystectomy: initial clinical experience with 25 patients[J]. Ann Surg,2001, 234(1): 1-7.
[3]Kobayashi Y,Moreira P, Liu Chao, et al. Haptic feedback control in medical robots through fractional viscoelastic tissue model[C] //33rd Annual International Conference of the IEEE EMBS. Boston:2011:6074-6078.
[4]Tavakoli M, Patel RV, Moallem M. Haptic interaction in robotassisted endoscopic surgery: a sensorized endeffector[J]. Int J Med Robot, 2005, 1(2): 53-63.
[5]King CH, Culjat MO, Franco ML, et al. Tactile feedback induces reduced grasping force in robotassisted surgery[J]. IEEE Transactions on Haptics, 2009, 2(2): 103-110.[6]Okamura AM. Methods for haptic feedback in teleoperated robotassisted surgery[J]. Ind Rob, 2004, 31(6): 499-508.
[7]Burdea GC. Force and Touch Feedback for Virtual Reality[M]. John Wiley & Sons Inc, 1996 : 3-4.
[8]Wagner CR, Howe RD. Force feedback benefit depends on experience in multiple degree of freedom robotic surgery task[J]. IEEE Transactions on Robotics 2007, 23(6): 1235–1240.
[9]Dargahi J, Sedaghati R, Singh H, et al. Modeling and testing of an endoscopic piezoelectricbased tactile sensor[J]. Mechatronics, 2007, 17(8): 462-467.
[10]Bethea BT, Okamura A M, Kitagawa M, et al. Application of haptic feedback to robotic surgery[J]. J Laparoendosc Adv Surg Tech A, 2004, 14(3): 191-195.
[11]Wagner CR, Stylopoulos N, Jackson PG et al. The benefit of force feedback in surgery:Examination of blunt dissection[J]. Presence: Teleoperators and Virtual Environments 2007, 16(3): 252–262.
[12]Massie TH, Salisbury JK. The PHANToM haptic interface: a device for probing virtual objects// Proceedings of the ASME Winter Annual Meeting, Symposium on Haptic Interfaces for Virtual Environment and Teleoperator System. Chicago: Kluwer, 1994: 295-300.
[13]Yin Yingjie, Luo Zhiwei, Svinin M, et al. Hybrid control of multifingered robot hand for dexterous manipulation[C] // IEEE International conference on System, Man and Cybernetics. Washington, D.C: IEEE, 2003: 3639-3644.
[14]Bouzit M, Popescu G, Burdea G, et al. The rutgers masterII—new design forcefeedback glove [J]. IEEE/ASME Transactions on Mechatronics, 2002, 7(2): 256-263.[15]Sung GT, Gill IS. Robotic laparoscopic surgery: a comparison of the da Vinci and Zeus systems. [J].Urology, 2001,58(6):893-898.
[16]Hashizume M, Shimada M, Tomikawa M, et al. Early experiences of endoscopic procedures in general surgery assisted by a computerenhanced surgical system[J]. Surgical Endoscopy, 2002,16(8):1187-1189.
[17]Ortmaier T, Deml B, Kübler B, et al. Robot assisted force feedback surgery[M].Berlin: SpringerVerlag, 2007: 361–379.
[18]Wagner CR, Stylopoulos N, Howe RD. The role of force feedback in surgery: Analysis of blunt dissection[C]//10th Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems. Orlando: IEEE, 2002: 73-79.
[19]Reiley CE, Akinbiyi T, Burschka D, Effects of visual force feedback on robotassisted surgical task performance[J].The Journal of Thoracic and Cardiovascular Surgery 2008, 135(1): 196-202.
[20]Lee MH, Nicholls HR. Tactile sensing for mechatronicsa state of the art survey[J]. Mechatronics, 1999, 9(1): 1-31.
[21]Hidaka Y, Shiokawa Y, Tashiro K, et al. Development of an elastic tactile sensor emulating human fingers for telepresentation systems[C]//IEEE Sensors 2009 Conference. Christchurch: IEEE,2009 : 1919-1922.
[22]Su Zhe, Fishel JA, Yamamoto T, et al. Use of tactile feedback to control exploratory movements to characterize object compliance[J]. Frontiers in Neurorobotics,2012 ,6(7):1-9.
[23]Leven J, Burschka D, Kumar R, et al. DaVinci canvas: a telerobotic surgical system with integrated, robotassisted, laparoscopic ultrasound capability[J]. Med Image Comput Assist Interv, 2005, 8(1): 811-818.
[24]Hosseini M, Najarian S, Motaghinasab S, et al. Detection of tumours using a computational tactile sensing approach [J]. The International Journal of Medical Robotics and Computer Assisted Surgery, 2006, 2(4) :333-340.
[25]Dargahi J, Najarian S, Ramezanifard R. Graphical display of tactile sensing data with application in minimally invasive surgery [J]. Canadian Journal of Electrical and Computer Engineering, 2007, 32: 151-155.
[26]Miller, AP, Hammoud, Z, Son, JS, et al. Tactile imaging system for localizing lung nodules during video assisted thoracoscopic surgery[C] // IEEE International Conference on Robotics and Automation. Roma: IEEE, 2007: 2996-3001.
[27]Ottermo MV, Stavdahl O, Johansen TA. Design and performance of a prototype tactile shape display for minimally invasive surgery[J]. HapticsE Journal, 2008, 4(4):1-13.
[28]Howe RD, Peine WJ, Kontarinis DA, et al. Remote palpation technology for surgical applications[J].IEEE Engineering in Medicine and Biology Magazine, 1995, 14(3): 318–323.
[29]King CH, Culjat M O, Franco M L, et al. Optimization of a pneumatic balloon tactile display for robotassisted surgery based on human perception[J].IEEE Trans Biomed Eng,2008, 55(11): 2593-2600.
[30]Lee DH, Park J, Yun K. Threeaxis tactile display using PDMS pneumatic actuator for robotassisted surgery [C] //Proceedings of the 16th International Conference of SolidState Sensors, Actuators and Microsystems. Beijing: IEEE, 出版者,2011: 2418-2421.
[31]Yamamoto T, Vagvolgyi B, Balaji K, et al. Tissue property estimation and graphical display for teleoperated robotassisted surgery[C] //Robotics and Automation. Kobe: 举办城市:出版者, IEEE , 2009: 4239-4245.