|
|
Three-Dimensional Reconstruction and Finite Element Analysis of Rat Trabecular Meshwork Basing on Two-Photon Microscope Images |
Zhang Jing, Qian Xiuqing, Zhang Haixia, Ren Lin, Liu Zhicheng#* |
Beijing Key Laboratory of Fundamental Research on Biomechanics in Clinical Application,School of Biomedical Engineering, Capital Medical University, Beijing 100069, China |
|
|
Abstract Glaucoma is a disease of irreversible blindness with the most risk factors of ocular hypertension that causes damage to the visual function and optic nerve. So far, clinical evidence indicates that increased intraocular pressure (IOP) is a function of elevated resistance to drainage of aqueous humor, especially the increase of outflow resistance within the trabecular meshwork (TM). Therefore, it is very important to figure out what effects of high IOP on the structures of TM and analyze the morphologic changes of TM contributing to the increase of outflow resistance in turn. In this study, animal model of acute IOP of rat was established by methods of anterior chamber perfusion. Six SD rats were divided into A, B two groups. After being killed, the left eyes of the SD rats in group B were perfused at pressure of 60 mmHg for imaging under the condition of ocular hypertension, and the other eyes was used as the control group. The tomographic sequence images of TM were obtained in the condition of normal or high IOP by using two-photon microscopy. The effects of IOP on the TM porosity based on image processing were quantitatively investigated. The three-dimensional model of TM was obtained in the normal IOP eye, and the morphological changes of TM were analyzed under different intraocular pressures by using the finite element method. The effect of high IOP on the outflow resistance of TM was analyzed by using the experiment integrated with the simulation method. In the high IOP group, the TM beams became collapsed and merged with surrounding tissues, and the damage of TM tissue near the anterior chamber is more serious. Through the analysis of finite element method, it was found out that the biggest deformation was located in the region that the porosity of TM was larger. Meanwhile, it was indicated that the greater the pressure was, the greater the damages of TM beams was. Eyes with the high IOP may cause the structural changes of TM. Fibers of TM were collapsed. The possibility of increasing outflow resistance could occur in high IOP eyes but was much smaller in normal eyes.
|
Received: 25 June 2017
|
|
Corresponding Authors:
E-mail: zcliu@ccmu.edu.cn
|
|
|
|
[1] Weinreb RN, Aung T, Medeiros FA. The pathophysiology and treatment of glaucoma: areview[J]. JAMA, 2014, 311 (18): 1901-1911.
[2] 汪俊, 崔巍. 我国原发性青光眼流行病学研究进展[J]. 国际眼科杂志, 2012, 12(4): 667-670.
[3] Tham YC, Li X, Wong TY. Global prevalence of glaucoma and projections of glaucoma burden through 2040: a systematic review and meta-analysis[J]. Ophthalmology, 2014, 121(11): 2081-2090.
[4] 胡倩倩, 吴仁毅. 青光眼视神经保护的治疗现状及进展[J]. 国际眼科杂志,2014,14(4):633-636.
[5] Stamer WD, Acott TS. Current understanding of conventional outflow dysfunction in glaucoma[J]. Curr Opin Ophthalmol, 2012, 23(2):135-143.
[6] Kagemann L, Wollstein G, Ishikawa H, et al. Identification and assessment of Schlemm′s canal by spectral domain optical coherence tomography[J]. Invest Ophthalmol Vis Sci, 2010, 51(8):4054-4059.
[7] Irshad FA, Mayfield MS, Zurakowski D, et al. Variation in Schlemm′s canal diameter andlocation by ultrasound biomicroscopy[J]. Ophthalmology, 2010, 117:916-920.
[8] Gibson EA, Masihzadeh O, Lei TC, et al.Multiphoton microscopy for ophthalmic imaging[J]. J Ophthalmol, 2011, 2011(2090-004X):870879.
[9] Gonzalez JM, Ammar MJ, Ko MHK, et al. Optimizing two-photon multiple fluorophore imaging of the human trabecular meshwork[J]. Molecular Vision, 2016, 22:203-212.
[10] Gonzalez JM, Heur M, Tan JCH. Two-photon immunofluorescence characterization of the trabecular meshwork in situ[J]. Invest Ophthalmol Vis Sci, 2012, 53(7): 3395-3404.
[11] Masihzadeh O, Ammar DA, Kahook MY, et al. Direct trabecular meshwork imaging in porcine eyes through multiphotongonioscopy[J]. Journal of Biomedical Optics, 2013, 18(3): 036009.
[12] Huang Jianyong, Camras LJ, Yuan Fan. Mechanical analysis of rat trabecular meshwork[J]. Soft Matter, 2015, 11(14):2857-2865.
[13] Mäepea O, Bill A. The pressures in the episcleral veins, Schlemm’s canal and the trabecular meshwork in monkeys:Effects of changes in intraocular pressure[J]. Exp Eye Res, 1989, 49(4):645-663.
[14] Goel M, Picciani RG, Lee RK, et al. Aqueous humor dynamics: areview[J]. Open Ophthalmology Journal, 2010, 4 (4): 52-59.
[15] Moayed AA, Bizheva K, Sorbara L, et al.In vivo volumetric imaging of the human corneo-scleral limbus with spectral domain OCT[J]. Biomedical Optics Express, 2011, 2(7): 1794-1702.
[16] Ishikawa H. and Schuman JS. Anterior segment imaging: ultrasound biomicroscopy[J]. Ophthalmology Clinics of North America, 2004, 17(1): 7-20.
[17] Zhang Xianzeng, Liu Nenrong, Peng UM, et al. Three-dimensional segmentation and quantitative measurement of the aqueous outflow system of intact mouse eyes based on spectral two-photon microscopy techniques[J]. Invest Ophthalmol Vis Sci, 2016, 57(7):3159-3167.
[18] Johnson M. What controls aqueous humour outflow resistance?[J].Exp Eye Res, 2006, 82(4):545-557.
[19] BaranyEH. In vitro studies on the resistance to flow through the angle of the anterior chamber[J]. Acta Soc Med Ups, 1954, 59(3-4):260-276.
[20] Tamm ER. The trabecular meshwork outflow pathways: Structural and functional aspects[J]. Exp Eye Res, 2009, 88(4): 648-655.
[21] McEwen WK. Application of Poiseuille’s law to aqueous outflow[J]. Archives of Ophthamology, 1958, 60(2): 290-294.
[22] Ethier CR, Kamm RD, Palaszewski BA, et al.Calculation of flow resistance in the juxtacanalicular meshwork[J].Invest Ophthalmol Vis Sci, 1986, 27(12): 1741-1750.
[23] Villamarina A,Roya S, Hasballa R, et al.3D simulation of the aqueous flow in the human eye[J]. Medical Engineering & Physics, 2012, 34: 1462-1470.
[24] ZhangJing,Ren Lin, Mei Xi,et al.Microstructure visualization of conventional outflow pathway and finite element modeling analysis of trabecular meshwork[J]. Biomedical Engineering Online, 2016, 15(2):323-334. |
[1] |
Xie Yixiang, Zhang Han, Zhu Weiping. Effect of Segmental Curvature on Stress Evolution of Lumbar Intervertebral Disc under Axial Vibration[J]. Chinese Journal of Biomedical Engineering, 2020, 39(1): 74-83. |
[2] |
Jin Qiankun, Wang Wei, He Shengwei, He Feixiong, Chen Bingzhi, Fu Yanmian. The Optimized Analysis on the Distribution Gradient of Material Attributes of Femur Finite Element Model[J]. Chinese Journal of Biomedical Engineering, 2020, 39(1): 84-90. |
|
|
|
|