|
|
Effect of Segmental Curvature on Stress Evolution of Lumbar Intervertebral Disc under Axial Vibration |
Xie Yixiang, Zhang Han, Zhu Weiping* |
(Shanghai Institute of Applied Mathematics and Mechanics, Shanghai University, Shanghai 200072, China) |
|
|
Abstract To study the effect of segmental curvature on the stress evolution of lumbar intervertebral disc when the lumbar motion segment is subjected to long-term axial vibration. Based on the CT scan data of human lumbar spine L4~5 segment, the finite element model of human lumbar spine L4~5 segment was constructed. Poroelastic property was assigned to the intervertebral disc and the finite element model was validated. Based on this finite element model, processes of L4~5 segment subjected to a 1000-s axial vibration with different segmental curvatures (neutral posture, 2° of extension, 2° of flexion) were simulated, and the stress evolution of the intervertebral disc in those cases were obtained. With each segmental curvature, the peak axial stress of the annulus fibrosus of the intervertebral disc existed in its posterolateral part. With each segmental curvature, the peak axial stress of the annulus fibrosus increased nonlinearly and the growth rate was decreased. In all cases, the peak axial stress of the annulus fibrosus was inclined to an equilibrium state at 1000 s. At 1000 s, the peak axial stress of the annulus fibrosus in the case with the L4~5 segment in 2° of extension was 39% greater than that in the case with the L4~5 segment in neutral posture and 109% greater than that in the case with the L4~5 segment in 2° of flexion. With each curvature, the axial stress of the nucleus pulposus also increased nonlinearly and the growth rate was decreased. At 1000s, the axial stress of the nucleus pulposus in the case with the L4~5 segment in 2° of extension was slightly less than those in the other two cases. The intervertebral disc was damaged most severely when the L4~5 segment was loaded in 2° of extension, while it suffered the slightest damage when the L4~5 segment was loaded in 2° of flexion. When exposed to the whole body vibration for a long time, an extended posture of lumbar spine should be avoided, and a slight flexed posture of lumbar spine can protect the intervertebral disc.
|
Received: 22 February 2019
|
|
|
|
|
[1] Burström L, Nilsson T, Wahlström J. Whole-body vibration and the risk of low back pain and sciatica: a systematic review and meta-analysis[J]. Int Arch Occ Env Hea, 2015, 88(4):403-418.
[2] Thomas Edwards W, Ordway NR, Zheng Y, et al. Peak stresses observed in the posterior lateral anulus[J]. Spine, 2001, 26(16):1753-1759.
[3] Lotz JC, Colliou OK, Chin JR, et al. Compression-induced degeneration of the intervertebral disc: an in vivo mouse model and finite-element study[J]. Spine, 1998, 23(23):2493-2506.
[4] Rannou F, Lee TS, Zhou RH, et al. Intervertebral disc degeneration: The role of the mitochondrial pathway in annulus fibrosus cell apoptosis induced by overload[J]. Am J Pathol, 2004, 164(3):915-924.
[5] 张涵,朱卫平.起床过程中腰椎应力动力学响应[J].医用生物力学,2017, 32(4):348-354.
[6] 原芳,薛清华,刘伟强.有限元法在脊柱生物力学应用中的新进展[J].医用生物力学,2013,28(5):585-590.
[7] Vergroesen PA, Veen AJ, Emanuel KS, et al. The poro-elastic behaviour of the intervertebral disc: A new perspective on diurnal fluid flow[J]. J Biomech, 2015, 49(6):857-863.
[8] Schmidt H, Shirazi-Adl A, Galbusera F, et al. Response analysis of the lumbar spine during regular daily activities—A finite element analysis[J]. J Biomech, 2010, 43(10):1849-1856.
[9] Guo Lixin, Teo EC, Lee KK, et al. Vibration characteristics of the human spine under axial cyclic loads: effect of frequency and damping[J]. Spine, 2005, 30(6):631-637.
[10] Fan Wei, Guo Lixin. Finite element investigation of the effect of nucleus removal on vibration characteristics of the lumbar spine under a compressive follower preload[J]. J Mech Behav Biomed Mater, 2018. 78:342-351.
[11] Cheung JT, Zhang Ming, Chow DH. Biomechanical responses of the intervertebral joints to static and vibrational loading: A finite element study.[J]. Clin Biomech, 2003, 18(9):790-799.
[12] 李睿,郭立新.低频振动作用下人体椎间盘多孔弹性单元的研究[J].应用力学学报,2013,(4):635-640.
[13] Nguyen TD, Oloyede A, Singh S, et al. Microscale consolidation analysis of relaxation behavior of single living chondrocytes subjected to varying strain-rates[J]. J Mech Behav Biomed Mater, 2015, 49:343-354.
[14] Adams MA, Freeman BJC, Morrison HP, et al. Mechanical initiation of intervertebral disc degeneration[J]. Spine, 2000, 25(13):1625-1636.
[15] 方新果,赵改平,王晨曦,等.基于CT图像腰椎L4~L5节段有限元模型建立与分析[J].中国生物医学工程学报,2014,33(4):487-492.
[16] 秦计生,王昱,彭雄奇,等.全腰椎三维有限元模型的建立及其有效性验证[J].医用生物力学,2013,28(3):321-325.
[17] Fazzalari NL, Parkinson IH, Fogg QA, et al. Antero-postero differences in cortical thickness and cortical porosity of T12 to L5 vertebral bodies[J]. Joint Bone Spine, 2006, 73(3): 293-297.
[18] Roberts S, Menage J, Urban JPG. Biochemical and structural properties of the cartilage end-plate and its relation to the intervertebral disc[J]. Spine, 1989, 14(2): 166-174.
[19] Zehra U, Robson-Brown K, Adams MA, et al. Porosity and thickness of the vertebral endplate depend on local mechanical loading [J]. Spine, 2015, 40(15): 1173-1180.
[20] Eberlein R, Holzapfel GA, Schulze-Bauer CAJ. An anisotropic model for annulus tissue and enhanced finite element analyses of intact lumbar disc bodies[J]. Comput Methods Biomech Biomed Engin, 2001, 4(3):209-229.
[21] 刘宝胜,杨庆生.椎体-椎间盘固液耦合的轴对称表达、建模与分析[J].医用生物力学,2007,22(4):361-366.
[22] Fan Ruoxun, Gong He, Qiu Sen, et al. Effects of resting modes on human lumbar spines with different levels of degenerated intervertebral discs: A finite element investigation[J]. BMC Musculoskelet Disord, 2015, 16(1):221.
[23] Schmidt H, Bashkuev M, Galbusera F, et al. Finite element study of human lumbar disc nucleus replacements[J]. Comput Methods Biomech Biomed Engin, 2014, 17(16):1762-1776.
[24] Zhang Han, Zhu Weiping. The path to deliver the most realistic follower load for a lumbar spine in standing posture: A finite element study[J]. J Biomech Eng, 2019, 141(3):031010.
[25] Woldtvedt DJ, Womack W, Gadomski BC, et al. Finite element lumbar spine facet contact parameter predictions are affected by the cartilage thickness distribution and initial joint gap size[J]. J Biomech Eng, 2011, 133(6):061009.
[26] Argoubi M, Shirazi-Adl A. Poroelastic creep response analysis of a lumbar motion segment in compression[J]. J Biomech, 1996, 29(10):1331-1339.
[27] Fan Wei, Guo Lixin. The role of posterior screw fixation in single-level transforaminal lumbar interbody fusion during whole body vibration: A finite element study[J]. World Neurosurg, 2018, 114:e1086-e1093.
[28] Hill TE, Desmoulin GT, Hunter CJ. Is vibration truly an injurious stimulus in the human spine?[J]. J Biomech, 2009, 42(16):2631-2635.
[29] Steffen T, Baramki HG, Rubin R, et al. Lumbar intradiscal pressure measured in the anterior and posterolateral annular regions during asymmetrical loading[J]. Clin Biomech, 1998, 13(7):495-505.
[30] Kuo YJ, Wu LC, Sun JS, et al. Mechanical stress-induced apoptosis of nucleus pulposus cells: an in vitro and in vivo rat model[J]. J Orthop Sci, 2014, 19(2):313-322.
[31] Fahrni WH. Conservative treatment of lumbar disc degeneration: our primary responsibility[J]. Orthop Clin N Am, 1975, 6(1): 93-103.
[32] Adams MA, Hutton WC. The effect of posture on the lumbar spine[J]. J Bone Joint Surg Br, 1985, 67(4): 625-629.
[33] Noguchi M, Gooyers CE, Karakolis T, et al. Is intervertebral disc pressure linked to herniation?: An in-vitro study using a porcine model[J]. J Biomech, 2016, 49(9): 1824-1830. |
[1] |
Jin Qiankun, Wang Wei, He Shengwei, He Feixiong, Chen Bingzhi, Fu Yanmian. The Optimized Analysis on the Distribution Gradient of Material Attributes of Femur Finite Element Model[J]. Chinese Journal of Biomedical Engineering, 2020, 39(1): 84-90. |
[2] |
Fang Runxin, Ji Aimin, Chen Changsheng, Long Dengyan, Zhao Zhonghang. Bone Healing Analysis of Transverse and Oblique Fracture Under Different Internal Fixation Parameters[J]. Chinese Journal of Biomedical Engineering, 2019, 38(4): 438-446. |
|
|
|
|