[1]Yang SS, Tang L, Ge GH, et al. Metaanalysis of the long term effects of different interventions on chronic total coronary occlusions [J]. Eur Rev Med Pharmacol Sci, 2013, 17(12): 1583-1589.
[2]Alcalai R, Viola N, Mosseri M, et al. The value of percutaneous coronary intervention in aortic valve stenosis with coronary artery disease [J]. Am J Med, 2007, 120(2): 185.e7-185.e13.
[3]Chatzizisis YS, Coskun AU, Jonas M, et al. Role of endothelial shear stress in the natural history of coronary atherosclerosis and vascular remodeling: molecular, cellular, and vascular behavior [J]. J Am Coll Cardiol, 2007, 49(25): 2379-2393.
[4]Papafaklis MI, Koskinas KC, Chatzizisis YS, et al. Invivo assessment of the natural history of coronary atherosclerosis: vascular remodeling and endothelial shear stress determine the complexity of atherosclerotic disease progression [J]. Curr Opin Cardiol, 2010, 25(6): 627-638.
[5]Koskinas KC, Chatzizisis YS, Antoniadis AP, et al. Role of Endothelial Shear Stress in Stent Restenosis and Thrombosis, Pathophysiologic Mechanisms and Implications for Clinical Translation [J]. J Am Coll Cardiol, 2012, 59(15): 1337-1349.
[6]Barakat AI. Blood flow and arterial endothelial dysfunction: Mechanisms and implications [J]. Cr Phys, 2013, 14(6): 479-496.
[7]Murphy J, Boyle F. Predicting neointimal hyperplasia in stented arteries using timedependant computational fluid dynamics: a review [J]. Comput Biol Med, 2010, 40(4): 408-418.
[8]LaDisa JF Jr, Guler I, Olson LE, et al. Threedimensional computtional fluid dynamic modeling of alterations in coronary wall shear stress produced by stent implantation [J]. Ann Biomed Eng, 2003, 31(8): 972-980.
[9]LaDisa JF Jr, Olson LE, Douglas HA, et al. Alterations in regional vascular geometry produced by theoretical stent implantation influence distributions of wall shear stress: analysis of a curved coronary artery using 3D computational fluid dynamics modeling [J]. Biomed Eng Online, 2006, 5:40.
[10]孙安强, 邓小燕. 冠状动脉支架血流动力学中的几个问题 [J]. 生物物理学报, 2011, 27(8): 669-675.
[11]Chen HY, Hermiller J, Sinha AK, et al. Effects of stent sizing on endothelial and vessel wall stress: Potential mechanisms for instent restenosis [J]. J Appl Physiol, 2009, 106(5): 1686-1691.
[12]Jimenez JM, Davies PF. Hemodynamically driven stent strut design [J]. Ann Biomed Eng, 2009, 37(8): 1483-1494.
[13]Mejia J, Ruzzeh B, Mongrain R, et al. Evaluation of the effect of stent strut profile on shear stress distribution using statistical moments [J]. Biomed Eng Online, 2009, 8:8.[14]LaDisa JF Jr, Olson LE, Guler I, et al. Stent design properties and deployment ratio influence indexes of wall shear stress: a threedimensional computational fluid dynamics investigation within a normal artery [J]. J Appl Physiol, 2004, 97(1): 424-430.
[15]Murasato Y, Hikichi Y, Horiuchi M. Examination of stent deformation and gap formation after complex stenting of left main coronary artery bifurcations using microfocus computed tomography [J]. J Interv Cardiol, 2009, 22(2):135-144.
[16]Katritsis DG, Theodorakakos A, Pantos I, et al. Flow patterns at stented coronary bifurcations computational fluid dynamics analysis [J]. Circ Cardiovasc Interv, 2012, 5(4): 530-539.
[17]Carlier SG, van Damme LC, Blommerde CP, et al. Augmentation of wall shear stress inhibits neointimal hyperplasia after stent implantation: inhibition through reduction of inflammation? [J]. Circulation, 2003, 107(21): 2741-2746.
[18]LaDisa JF Jr, Olson LE, Molthen RC, et al. Alterations in wall shear stress predict sites of neointimal hyperplasia after stent implantation in rabbit iliac arteries [J]. Am J Physiol Heart Circ Physiol, 2005, 288(5): H2465-H2475.
[19]Fujimoto M, Takao H, Suzuki T, et al. Temporal correlation between wall shear stress and instent stenosis after wingspan stent in swine model [J]. AJNR Am J Neuroradiol, 2014, 35(5): 994-998.
[20]Morlacchi S, Keller B, Arcangeli P, et al. Hemodynamics and instent restenosis: microCT images, histology, and computer simulations [J]. Ann Biomed Eng, 2011, 3910): 2615-2626.
[21]Virmani R, Kolodgie FD, Farb A, et al. Drug eluting stents: are human and animal studies comparable? Heart, 2003, 89:133-138.
[22]Wentzel JJ, Krams R, Schuurbiers JC, et al. Relationship between neointimal thickness and shear stress after Wallstent implantation in human coronary arteries [J]. Circulation, 2001, 103(13): 1740 -1745.
[23]Stone PH, Coskun AU, Kinlay S, et al. Effect of endothelial shear stress on the progression of coronary artery disease, vascular remodeling, and instent restenosis in humans: in vivo 6-month followup study [J]. Circulation, 2003,
108(4): 438-444.
[24]Sanmartin M, Goicolea J, Garcia C, et al. Influence of shear stress on instent restenosis: in vivo study using 3D reconstruction and computational fluid dynamics [J]. Rev Esp Cardiol, 2006, 59(1): 20-27.
[25]Gijsen FJ, Oortman RM, Wentzel JJ, et al. Usefulness of shear stress pattern in predicting neointima distribution in sirolimuseluting stents in coronary arteries [J]. Am J Cardiol, 2003, 92(11): 1325-1328.
[26]Papafaklis MI, Katsouras CS, Theodorakis PE, et al. Coronary dilatation 10 weeks after paclitaxeleluting stent implantation. No role of shear stress in lumen enlargement? [J]. Heart Vessels, 2007, 22(4): 268-273.
[27]Suzuki N, Nanda H, Angiolillo D J, et al. Assessment of potential relationship between wall shear stress and arterial wall response after bare metal stent and sirolimuseluting stent implantation in patients with diabetes mellitus[J]. Int J Cardiovasc Imag, 2008, 24(4): 357-364.
[28]Gundert TJ, Shadden SC, Williams AR, et al. A rapid and computationally inexpensive method to virtually implant current and nextgeneration stents into subjectspecific computational fluid dynamics models [J]. Ann Biomed Eng, 2011, 39(5):1423-1437.
[29]Morlacchi S, Migliavacca F. Modeling stented coronary arteries: where we are, where to go [J]. Ann Biomed Eng, 2013, 41(7): 1428-1444.
[30]Zhang Junmei, Zhong Liang, Su Boyang, et al. Perspective on CFD studies of coronary artery disease lesions and hemodynamics: A review [J]. Int J Numer Method Biomed Eng, 2014, 30(6): 659-680.
[31]Chiastra C, Migliavacca F, Martinez MA, et al. On the necessity of modelling fluidstructure interaction for stented coronary arteries [J]. J Mech Behav Biomed Mater, 2014, 34: 217-230.
|