Study on Thermo-Acoustic Effect in Magneto-Acoustic Tomography with Magnetic Induction |
Yang Ming#, Ma Ren#, Zhang Shunqi#, Zhou Xiaoqing#, Yin Tao#, Liu Zhipeng#* |
Institute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300192, China |
|
|
Abstract The aim of this paper was to investigate the thermo-acoustic (TA) effect in magneto-acoustic tomography with magnetic induction (MAT-MI) and analyze the characteristics of distribution and amplitude of magneto-acoustic (MA) source and thermo-acoustic source.Expressions of MA and TA sources were established. The induced current distribution, MA+TA source distribution and sound pressure of the multi-layer conductivity simulation model were calculated by numerical simulation. The results of the two kinds of source distribution and reconstruction were compared. To verify the simulation model, MAT experimental platform was built, and the experiments of MA and TA were carried out with a conductive rubber ring. The amplitude and reconstruction results of MA and TA signals were compared and analyzed.Numerical simulation showed that MA source concentrated at the conductivity boundary, while TA source was widely distributed at both the boundary and the inside. The maximum value of MA source was 15 times of TA source. Phantom experiments showed that the peak to peak value of TA signal was a quarter of mixed signal. The reconstructed boundary of TA was fuzzy, while that of MA was clear but contained artifacts. The results of simulation and experiment proved that TA effect existed in MAT. The distribution of TA source and the amplitude relationship between MA and TA signals suggested that TA effect partly affected the result of MAT.
|
Received: 20 January 2020
|
|
|
|
|
[1] Li Xu, Xu Yuan, He Bin. Imaging electrical impedance from acoustic measurements by means of magnetoacoustic tomography with magnetic induction (MAT-MI) [J]. IEEE Transactions on Biomedical Engineering, 2007, 54(2): 323-330. [2] Li Xu, Yu Kai, He Bin. Magnetoacoustic tomography with magnetic induction (MAT-MI) for imaging electrical conductivity of biological tissue: a tutorial review [J]. Physics in Medicine and Biology, 2016, 61(18): R249-R270. [3] Xu Yuan, He Bin. Magnetoacoustic tomography with magnetic induction (MAT-MI) [J]. Physics in Medicine and Biology, 2005, 50(21): 5175-5187. [4] Mariappan L, He Bin. Magnetoacoustic tomography with magnetic induction: bioimepedance reconstruction through vector source imaging [J]. IEEE Transactions on Medical Imaging, 2013, 32(3): 619-627. [5] Sun Xiaodong, Zhang Feng, Ma Qingyu, et al. Acoustic dipole radiation based conductivity image reconstruction for magnetoacoustic tomography with magnetic induction [J]. Applied Physics Letters, 2012, 100(2): 024105. [6] Xia Rongmin, Li Xu, He Bin. Comparison study of three different image reconstruction algorithms for MAT-MI [J]. IEEE Transactions on Biomedical Engineering, 2010, 57(3): 708-713. [7] Hu Gang, Cressman E, He Bin. Magnetoacoustic imaging of human liver tumor with magnetic induction [J]. Applied Physics Letters, 2011, 98(2): 023703. [8] Li Xu, Xu Yuan, He Bin. Magnetoacoustic tomography with magnetic induction for imaging electrical impedance of biological tissue [J]. Journal of Applied Physics, 2006, 99(6): 066112. [9] Sun Xiaodong, Fang Dawei, Zhang Dong, et al. Acoustic dipole radiation based electrical impedance contrast imaging approach of magnetoacoustic tomography with magnetic induction [J]. Medical Physics, 2013, 40(5): 052902. [10] Feng Xiaohua, Gao Fei, Zheng Yuanjin. Magnetically mediated thermoacoustic imaging toward deeper penetration [J]. Applied Physics Letters, 2013, 103(8): 083704. [11] Feng Xiaohua, Gao Fei, Kishor R, et al. Coexisting and mixing phenomena of thermoacoustic and magnetoacoustic waves in water [J]. Scientific Reports, 2015, 5(1): 11489. [12] 李俊霖, 周晓青, 殷涛, 等. 注入式磁声成像中热声效应的初探 [J]. 生物医学工程研究, 2016, 35(3): 145-150. [13] 周晓青, 刘世坤, 张鑫山, 等. 热声效应对磁声信号的频率影响分析 [J]. 医疗卫生装备, 2018, 39(1): 41-45. [14] Zhou Xiaoqing, Ma Ren, Zhang Wei, et al. Experimental study of the thermoacoustic effect in magnetoacoustic tomography [J]. AIP Advances, 2016, 6(9): 095008. [15] 李艳红, 刘国强, 宋佳祥, 等. 基于热吸收分布的热声成像方法研究 [J]. 中国科学:技术科学, 2019, 49(6): 641-651. [16] 杨延菊, 刘国强, 夏正武. 脉冲磁激励的磁声效应和热声效应的仿真研究 [J]. 生物医学工程学杂志, 2017, 34(1): 21-26. [17] Li Yanhong, Liu Guoqiang, Xia Hui, et al. Conductivity reconstruction and numerical simulation for magnetically mediated thermoacoustic imaging [J]. IEEE Transactions on Magnetics, 2018, 54(3): 1-4. [18] Yang Yanju, Liu Guoqiang, Xia Hui, et al. Acoustic signal detection on magnetically mediated thermoacoustic imaging [C] //2016 IEEE International Conference on Signal and Image Processing (ICSIP). Beijing: IEEE, 2016, 417-420. [19] 杨延菊, 李艳红, 刘国强, 等. 磁热声成像的实验研究 [J]. 高电压技术, 2017, 43(8): 2518-2523. [20] Filippi P, Habault D, Lefebvre J-P, et al. Acoustics: Basic Physics, Theory and Methods [M]. San Diego: Academic Press, 1999: 1-27. |
|
|
|