|
|
The Influence of Cavity and Bony Structure on Dosimetry Evaluation in Nasopharyngeal CarcinomaIMRT Plans Using Different Algorithms |
Shen Zhengwen, Tan Xia, Li Shi, Tian Xiumei, Luo Huanli, Jin Fu#*, Wang Ying |
(Department of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing 400030, China) |
|
|
|
Received: 03 June 2021
|
|
Corresponding Authors:
*E-mail: jfazj@cqu.edu.cn
|
About author:: #Member, Chinese Society of Biomedical Engineering |
|
|
|
[1] 谭霞, 罗焕丽, 王颖, 等. 宫颈癌调强放疗在体剂量监测初步研究 [J]. 中华放射肿瘤学杂志, 2020, 29(9): 784-789. [2] 刘潇, 尹勇, 王莉, 等. 宫颈癌IMRT计划独立三维剂量验算的初步应用与探讨 [J]. 中华放射肿瘤学杂志, 2017, 26(4): 433-436. [3] 曹午飞, 陈立新, 邓小武, 等. 独立验算软件调强放疗质量控制可行性研究 [J]. 中华放射肿瘤学杂志, 2011, 20(6): 521-524. [4] 中国鼻咽癌临床分期工作委员会. 2010鼻咽癌调强放疗靶区及剂量设计指引专家共识 [J].中华放射肿瘤学杂志, 2011, 20(4): 267-269. [5] Sikora M, Dohm O, Alber M. A virtual photon source model of an Elekta linear accelerator with integrated mini MLC for Monte Carlo based IMRT dose calculation [J]. Phys Med Biol, 2007, 52(15): 4449-4463. [6] Sikora M, Alber M. A virtual source model of electron contamination of a therapeutic photon beam [J]. Phys Med Biol, 2009, 54(24): 7329-7344. [7] Nordstrom F, Wetterstedt S, Johnsson S. Control chart analysis of data from a multicenter monitor unit verification study [J]. Radiother Oncol, 2012, 102(3): 364-370. [8] Hoffmann L, Alber M, Shn M, et al. Validation of the Acuros XB dose calculation algorithm versus Monte Carlo for clinical treatment plans [J]. Med Phys, 2018, 45(8): 1-7. [9] 傅玉川, 唐斌, 李平. 基于蒙特卡罗算法的肿瘤放射治疗计划系统的研究进展 [J]. 华西医学, 2010, 4(12): 2129-2132. [10] Vassiliev ON, Wareing TA, Mcghee J, et al. Validation of a new grid-based Boltzmann equation solver for dose calculation in radiotherapy with photon beams [J]. Phys Med Biol, 2010, 55(3): 581-598. [11] Han T, Mourtada F, Kisling K, et al. Experimental validation of deterministic Acuros XB algorithm for IMRT and VMAT dose calculations with the Radiological Physics Center's head and neck phantom [J]. Med Phys, 2012, 39(4): 2193-2202. [12] Ma CM, Li J. Dose specification for radiation therapy: dose to water or dose to medium? [J]. Phys Med Biol, 2011, 56(10): 3073-3089. [13] Bush K , Gagne I M , Zavgorodni S , et al. Dosimetric validation of AcurosXB with Monte Carlo methods for photon dose calculations [J]. Med Phys, 2011, 38(4): 2208-2221. [14] 姚凯宁, 岳海振, 王若曦, 等. 基于蒙特卡罗模拟的直肠癌术前容积调强放射治疗计划剂量验证 [J]. 中国医学物理学杂志, 2020, 37 (5): 7-12. [15] Han T, Mikell JK, Salehpour M, et al. Dosimetric comparison of AcurosXB deterministic radiation transport method with Monte Carlo and model-based convolution methods in heterogeneous media [J]. Med Phys, 2011, 38(5): 2651-2664. [16] Rana S, Rogers K. Dosimetric evaluation of Acuros XB dose calculation algorithm with measurements in predicting doses beyond different air gap thickness for smaller and larger field sizes [J]. J Med Phys, 2013, 38(1): 9-14. [17] Kan MW, Leung LH, So RW, et al. Experimental verification of the Acuros XB and AAA dose calculation adjacent to heterogeneous media for IMRT and RapidArc of nasopharygeal carcinoma [J]. Med Phys, 2013, 40(3): 031714. [18] Kan MW, Leung LH, Yu PK. Dosimetric impact of using the Acuros XB algorithm for intensity modulated radiation therapy and RapidArc planning in nasopharyngeal carcinomas [J]. Int J Radiat Oncol Biol Phys, 2013, 85(1): e73-e80. |
|
|
|