Detecting and Locating the Macular Using Morphological Features and k-means Clustering |
Cao Xinrong1,2* , Lin Jiawen1, Xue Lanyan1, Yu Lun1 |
1School of Physics and Information Engineering, Fuzhou University, Fuzhou 350116, China 2Fujian Provincial Key Laboratory of Information Processing and Intelligent Control, Minjiang University, Fuzhou 350121, China |
|
|
Abstract Color fundus images have been widely used in the diagnosis and screening of ophthalmic diseases. The macular detection and foveal location in fundus images are important steps in grading and diagnosis of ophthalmic diseases. An efficient method not relying on the optic and vascular information was proposed in this work for detecting and locating macular foveal. After a general analysis on morphological characteristics of macular, which was low brightness and round, the area of macular could be ensured in the binary images. Then, an improvedk-means clustering method was proposed on the basis of spatial information of images and optimizes clustering objects to obtain the edge information of macular and achieve accurate position of the macula foveal. Experimental tests showed good performance in the public fundus images database. For the normal and the pathological changes of the fundus images, the effective location rate of the macula was 96.11% and 92.12% respectively, and the average accuracy reached 93.92%. Thus the proposed method based on morphological features and k-means clustering proved a simple, efficient and useful tool for computer-aided diagnosis of ocular diseases.
|
Received: 26 March 2017
|
|
|
|
|
[1] 邹北骥, 张思剑, 朱承璋. 彩色眼底图像视盘自动定位与分割[J]. 光学精密工程, 2015, 23(4): 1187-1195. [2] Abràmoff MD, Garvin MK, Sonka M. Retinal imaging and image analysis[J]. IEEE Trans Med Imaging, 2010, 3: 169-208. [3] Besenczi R, Tóth J, Hajdu A. A review on automatic analysis techniques for color fundus photographs[J]. Computational and Structural Biotechnology Journal, 2016, 14: 371-384. [4] Antal B, Hajdu A. A Stochastic Approach to Improve Macula Detection in Retinal Images[J]. Acta Cybern, 2011, 20(1): 5-15. [5] Deepak KS, Sivaswamy J. Automatic assessment of macular edema from color retinal images[J]. IEEE Transactions on Medical Imaging, 2012, 31(3): 766-776. [6] Cheng J, Wong DWK, Cheng X, et al. Early age-related macular degeneration detection by focal biologically inspired feature[C]//2012 19th IEEE International Conference on Image Processing.Orlando: IEEE, 2012: 2805-2808. [7] Burlina P, Freund D E, Joshi N, et al. Detection of age-related macular degeneration via deep learning[C]//2016 IEEE 13th International Symposium on Biomedical Imaging. Prague: IEEE, 2016: 184-188. [8] Liang Ziyang, Wong DWK, Liu Jiang, et al. Towards automatic detection of age-related macular degeneration in retinal fundus images[C] //2010 Annual International Conference of the IEEE\|EMBS.Buenos Aires: IEEE, 2010: 4100-4103. [9] Litvin TV, Weissenberg CR, Daskivich LP, et al. Improving accuracy of grading and referral of diabetic macular edema using location and extent of hard exudates in retinal photography[J]. Journal of Diabetes Science and Technology, 2016, 10(2): 262-270. [10] 中华医学会眼科学会眼底病学组.我国糖尿病视网膜病变临床诊疗指南(2014年)[J].中华眼科杂志,2014, 50(11):851-865. [11] Li H, Chutatape O. Automated feature extraction in color retinal images by a model based approach[J]. IEEE Transactions on Biomedical Engineering, 2004, 51(2): 246-254. [12] Fleming AD, Philip S, Goatman KA, et al. Automated assessment of diabetic retinal image quality based on clarity and field definition[J]. Investigative Ophthalmology & Visual Science, 2006, 47(3): 1120-1125. [13] Niemeijer M, Abramoff MD, Van Ginneken B. Segmentation of the optic disc, macula and vascular arch in fundus photographs[J]. IEEE Transactions on Medical Imaging, 2007, 26(1): 116-127. [14] Niemeijer M, Abràmoff MD, Van Ginneken B. Fast detection of the optic disc and fovea in color fundus photographs[J]. Medical Image Analysis, 2009, 13(6): 859-870. [15] 郑绍华,陈健,潘林,等. 眼底图像中黄斑中心与视盘自动检测新方法[J]. 电子与信息学报, 2014, 36(11): 2586-2592. [16] Gegundez-Arias ME, Marin D, Bravo JM, et al. Locating the fovea center position in digital fundus images using thresholding and feature extraction techniques[J]. Computerized Medical Imaging and Graphics, 2013, 37(5): 386-393. [17] Decencière E, Zhang X, Cazuguel G, et al. Feedback on a publicly distributed image database: The Messidor database[J]. Image Analysis and Stereology, 2014, 33(3): 231-234. [18] Barrigas, Zamara G, Soliz P. Fast localization of optic disc and fovea in retinal images for eye disease screening[J].Proceedings of SPIE, 2011, 2963(1):843\|845. [19] 肖志涛,赵北方,张芳,等. 基于k均值聚类和自适应模板匹配的眼底出血点检测方法[J]. 中国生物医学工程学报, 2015, 34(3): 264-271. [20] 陈强. 图像分割若干理论方法及应用研究[D]. 南京:南京理工大学, 2007. [21] 李建军, 徐亮, 彭晓燕, 等. 远程眼科单张眼底像质量标准 (征求意见稿)[J]. 眼科, 2015, 24 (1): 11-12. |
|
|
|