Abstract:The EEG of volunteers was collected when they were watching 3D images with different parallaxes. The visual evoked potential (VEP) of different images and the visual fatigue factor R were analyzed to explore the effects of parallax of 3D film on human body. Test systems were set up based on the Neuroscan electroencephalograph. Ten healthy volunteers received picture\|stimulation of different parallaxes. A feedback button could be pressed when they felt discomfort (tingling or vertigo). Through the method of superimposed average, VEP was extracted based on three lead O1, Oz, and O2 in occipital domain of visual sense, obtaining N135 composition and P260 composition wave. The preprocessed ECG signals were superposed upon the same stimulus serial number. The fatigue factor R was obtained from the relative power calculated by the superposed signals with Matlab. Results showed that the amplitudes and the latency period of the VEP were not the same while watching different visual parallax images, especially for the latency period (the variation of mean value between different groups was 30%). The fatigue factor R was the biggest when volunteers watched negative parallax 3D images, and the average values of all leads were 10% higher than that when watching other groups. In conclusions, the P260 component (amplitude and incubation period) can be used to detect 3D pictures; Negative parallax images more likely make human eyes fatigue; Images with both positive and negative parallaxes is in the least possibility to cause fatigue.
[1]Ntuen CA, Goings M, Reddin M. Comparison between 2D & 3D using an autostereoscopic display: The effects of viewing field and illumination on performance and visual fatigue [J]. International Journal of Industrial Ergonomics, 2009, 39(2): 388-395.
[2]梁雪玲. 带你全面了解3D技术[J]. 电子世界,2010,375(12):58-59.
[3]赵亮. 3D立体成像研究[J]. 科技信息, 2011 (8):10206-10206.
[4]杨会. 3D 电影华丽逆袭的交流革新[J]. 电影评介, 2014,5: 006.
[5]Yano S, Emoto M, Mitsuhashi T. Two factors in visual fatigue caused by stereoscopic HDTV images[J]. Displays, 2004, 25(4):141-150.
[6]郑华东,于瀛洁,程维明.三维立体显示技术研究新进展[J].光学技术, 2008, 34(3): 22-26.
[7]Ntuen CA, Goings M, Reddin M, et al. Comparison between 2\|D & 3\|D using an autostereoscopic display: The effects of viewing field and illumination on performance and visual fatigue [J]. International Journal of Industrial Ergonomics, 2009,39(2): 388-395.
[8]Yano S, Ide S, Mitsuhashi T, et al. A study of visual fatigue and visual comfort for 3D HDTV/HDTV images[J]. Displays, 2002, 23(2):191-201.
[9]Lambooij M, Ijsselsteijn WA, Heynderickx I. Visual discomfort of 3D TV: Assesment methods and modeling[J]. Displays, 2011,32(10):209-218.
[10]吴绍斌,高利,王刘安. 基于脑电信号的驾驶疲劳检测研究[J]. 北京理工大学学报, 2009, 29(12): 1073-1074.
[11]王小琴, 谢青. 立体视觉相关皮层的研究进展[J]. 中华眼视光学与视觉科学杂志, 2014,16(5): 318-320.
[12]王嘉辉, 程义, 李焜阳,等. 3D显示方式与视差对视觉疲劳的影响研究 [J]. 中山大学学报:自然科学版, 2013 (5):1-5.
[13]应根裕. 平板3 D电视与人眼生理 [J]. 现代显示, 2012, 23(10): 5-12.
[14]张莉,何为,何传红. 脑电伪迹消除方法的研究[C]//第十届全国电工数学学术年会论文集.北京:中国电机工程学会电工数学专业委员会, 2005:5.
[15]王昊文. 基于脑电的三维立体电视健康安全评价基础研究[D]. 南京:南京航空航天大学, 2013.
[16]刘晓燕. 临床脑电图学[M]. 北京:人民卫生出版社, 2006.
[17]张贯忠. 脑电伪迹去除与生物电睡眠特征提取[D]. 哈尔滨:哈尔滨工业大学, 2005.
[18]Buzsáki G, Logothetis N, Singer W. Scaling brain size, keeping timing: evolutionary preservation of brain rhythms[J]. Neuron, 2013, 80(3):751-764.
[19]宋伟琼, 谭浅, 夏朝华,等. 正常人视觉诱发电位的特征[J]. 国际眼科杂志, 2006, 6(2): 387-389.
[20]潘速跃, 杨文俊. 视觉事件相关电位中N_2、P_3潜伏期与反应时间[J]. 南方医科大学学报, 1996,16(1):12-14.
[21]Mollenhauer KA, Haase W. Preliminary report: Dynamic stereopsis in patients with impaired binocular function[J]. Strabismus, 2000, 8(4): 275-281.
[22]金帅,邢丽冬,钱志余,等. 3D影片中深度信息与观看者疲劳度的关联研究 [J]. 中国生物医学工程学报, 2014, 33(2):15-21.
[23]李桂苓,潘榕,许树檀. 立体视觉与立体成像 [J]. 电视技术, 2012, 36(2): 15-18.